Important Product Information 35
GFK-1671P
Open Issues and Problems
ID Description
CR72374
Store of Program Logic that contains a large number of Jump Instructions may cause
the store to fail.
Details: When you try to store a LD or IL program that contains a large number of Jump
instructions, the store may fail.
Resolution: The default Request Timeout should be changed as described below:
1) Open the CCU - Communication Configuration Utility (Go to the Tools menu and select
Communications Setup menu option)
2) Select the Ports Tab.
3) Select the communication port in use (say COM1) and click the Edit button.
3) Click the Advanced button on the Edit Port dialog.
4) Change the Request Timeout to 30000ms (30s).
5) Click the OK button.
6) Select the Global Parameters Tab.
7) Click the Edit button.
8) Change the Request Timeout to 30000ms (30s).
9) Click the OK Button.
10) Click the OK Button on the CCU dialog.
11) VersaPro must now be disconnected and reconnected from the PLC for the new time-out
parameters to take effect.
Cut/Copy/Paste Issues
ID Description
CR74483
Copy of variable row from Microsoft Access to Vardec of VersaPro unsuccessful.
Details: Open VersaPro and create a folder. Open Access and create two rows in it. In the first
Row define the following fields: Name, Type, Len, Address, Description, Stored Val, Ret, and
Ovr. In the second row , define: var1, INT, 1, %R00001, xyz, and 1. Now perform a copy on
the Second Row and attempt a paste in the Variable Declaration of VersaPro. An error
message box pops up saying “unable to paste.”
Resolution: VersaPro does not support Microsoft Access copy/paste formats. However,
VersaPro can import variables in comma-separated variables (csv) format, so you can export
the data in this format. Also, VersaPro supports copy/paste from Excel. You can export the
Access file to Excel format and then copy and paste from Excel.
DSM314 Local Logic, Motion Program and CAM Editor Issues
ID Description
CR70864
Motion and Local Logic Editors Displaying Unprintable characters under Windows 95.
Details: Create a comment text below using Microsoft Word as an editor (Times New Roman,
font size 10). When text is copied into local logic and motion editors, the four periods are
replaced with the unprintable square box and one dot. This occurs only when running under
Windows 95. It is not a problem on Windows NT.
//This is a simple comment that
//can be copied into an editor....
Resolution: When using Word as a text source for Motion programs, you should configure
Word to view only printable characters. This can be selected under Tools
®Options®View.